NEWS


A high-tech enterprise integrating R & D, production, sales and service of water pump products.

Precautions for the use of submersible pumps

2023-12-15


For the submersible pump should do some necessary checks before starting: whether the rotation of the pump shaft is normal, whether there is a stuck phenomenon; whether the position of the impeller is normal; whether the cable and cable plug is broken, scratched and broken. During operation, pay attention to the change of voltage, which is generally controlled within ± 5% of the rated voltage. In addition, the position of the pump in the water is very important. It should be selected as far as possible in a place with abundant water, no silt and good water quality. It should be suspended vertically in the water (note: never use cable to suspend it). It is not allowed to be placed horizontally, so as not to fall into mud or be blocked by suspended substances, resulting in sharp reduction of water output or even failure to pump water.

1, for the submersible pump should do some necessary checks before starting: whether the rotation of the pump shaft is normal, whether there is a stuck phenomenon; whether the position of the impeller is normal; whether the cable and cable plug is broken, scratched and broken. During operation, pay attention to the change of voltage, which is generally controlled within ± 5% of the rated voltage. In addition, the position of the pump in the water is very important. It should be selected as far as possible in a place with abundant water, no silt and good water quality. It should be suspended vertically in the water (note: never use cable to suspend it). It is not allowed to be placed horizontally, so as not to fall into mud or be blocked by suspended substances, resulting in sharp reduction of water output or even failure to pump water.

2. Water pump maintenance Once the water pump fails, do not disassemble it yourself. Because when disassembling by oneself, one is that one does not know where the fault is, causing blind disassembling. Second, there is no special tool and often damage the original intact parts. The best way is to go to an experienced, large-scale maintenance point for maintenance, and timely replacement of "over-age" parts and some wearing parts. Under normal circumstances, the pump should be repaired every six months.

3, long-term shutdown of the electric pump, the pump should be timely lifting away from the water source, and emptying the water in the pump, especially in the cold winter. Then place it in a dry place. Conditional users can also apply butter to the key parts of the water pump and add lubricating oil to the bearing to prevent parts from rusting. In addition, the non-use period of the pump is not the longer the better. If it is not used for a long time, it will not only easily rust the parts, but also reduce the service life of the pump.

Electric submersible pump

RELATED INFORMATION


Submersible pump installation and use of technical matters needing attention

Water Because the submersible pump unit is charged to dive into the water, the sealing and insulation performance of the motor must be reliable, and the installation and use technology must be strict. A little improper will cause problems, light will aggravate the wear of parts, heavy will burn the motor can not work. Therefore, the installation and use of submersible pump units must comply with the following technical points.

2023-12-15

Submersible pump: pressurized water pump for domestic water supply

The self-filling and water absorption of the domestic water supply pump does not require the pump to be located below the lowest water level of the storage tank. The self-filling suction pump cannot be started at the lowest water level of the storage tank. Therefore, the storage tank should set a pump-starting water level according to the self-filling requirements of the pump. When the water level is above the pump-starting water level, the pump is allowed to start. When the water level is below the pump-starting water level, the pump is not allowed to start. However, the pump already in operation should continue to run and stop automatically when the pump reaches the minimum water level of the storage tank (as long as long as long as required, it can continue to operate even below the minimum water level). Therefore, the pump top discharge hole of the horizontal centrifugal pump and the first stage (section) pump body of the suction end of the vertical multistage centrifugal pump can be placed below the lowest design water level elevation.

2023-12-15

How to effectively reduce the energy consumption of water pump

The internal surface of the water pump and the inner surface of the pressure water chamber (also known as the volute) are rusted and uneven. Surface corrosion bump will reduce the pump water volume by 7%-8%; Only steel brush and iron sandpaper or grinding wheel need to be polished smoothly during maintenance, which can reduce the fuel consumption or power consumption by 9%-14% during work.

2023-12-15

Quote Now